17 modules over 10 daysParticipants can identify fire development hazards and select appropriate initial response actions.
- Fire triangle, tetrahedron and heat transfer mechanisms affecting fire growth
- Classify ordinary combustibles, flammable liquids, gases, metals and cooking oils
- Match fire classes to suitable extinguishing media and limitations
- Identify ignition sources through electrical, hot-work and process hazard reviews
- Combustion products, smoke toxicity and tenability limits during evacuation
- Recognise flashover, backdraft and rapid fire development warning signs
Participants can specify preventive controls for common workplace fire hazards.
- Control combustible loading through storage limits and housekeeping inspections
- Segregate incompatible chemicals using safety data sheets and storage matrices
- Apply hot-work permit controls, fire watches and post-work monitoring
- Review electrical safety defects causing overheating, arcing and ignition
- Manage smoking, cooking and battery-charging hazards through designated controls
- Document preventive actions within inspection schedules and corrective-action registers
Participants can complete a structured fire risk assessment for a defined area.
- Define assessment scope, occupancy profiles, assets and operational boundaries
- Map ignition sources, fuel loads, oxygen sources and vulnerable persons
- Use likelihood-consequence scoring to prioritise fire risk scenarios
- Evaluate existing controls using prevention, protection and response categories
- Record residual risk, action owners, deadlines and verification evidence
- Review assessment findings after change, incident, drill or inspection
Participants can assess the purpose and operating readiness of fire detection and alarm arrangements.
- NFPA 72 principles for detection, notification, testing and impairment management
- Compare smoke, heat, flame and aspirating detection applications
- Interpret alarm zones, annunciator panels and supervisory signal indications
- Establish alarm investigation procedures without delaying evacuation decisions
- Manage system impairments through permits, compensatory measures and restoration checks
- Verify audibility, visibility and communication arrangements for varied occupancies
Participants can inspect fire suppression provisions and define safe conditions for first-response action.
- NFPA 10 extinguisher selection by hazard, travel distance and rating
- Inspect extinguishers for location, pressure, seals, damage and service status
- Compare water, foam, carbon dioxide, dry powder and wet chemical agents
- Explain sprinkler, standpipe, hose reel and gaseous suppression system functions
- Set safe intervention limits before evacuation becomes the required response
- Report impaired suppression equipment through escalation and temporary control arrangements
Participants can evaluate escape arrangements and prepare evacuation procedures for diverse occupants.
- NFPA 101 life-safety principles for exits, travel distance and occupancy
- Assess exit routes for width, obstructions, signage and door operation
- Calculate occupant loads and identify congestion points during evacuation
- Design assembly areas considering fire spread, traffic and emergency access
- Prepare personal emergency evacuation procedures for mobility and sensory needs
- Account for visitors, contractors, lone workers and remote work areas
Participants can organise fire warden coverage, duties and escalation arrangements.
- Define chief warden, floor warden, searcher and assembly coordinator duties
- Allocate warden coverage using shift patterns, occupancy and building layouts
- Conduct area sweeps without entering smoke-affected or unsafe spaces
- Use sweep status reports, accountability boards and escalation protocols
- Brief wardens on visitor control, contractor induction and accessibility needs
- Maintain warden appointment records, refresher schedules and competence evidence
Participants can establish clear emergency messages and communication channels during fire events.
- Draft alarm messages using location, hazard, action and accountability details
- Apply plain-language radio protocols during time-critical emergency communications
- Differentiate evacuation, shelter-in-place and partial evacuation communication triggers
- Coordinate public-address announcements, radios, telephones and messaging platforms
- Control misinformation through designated spokespersons and verified situation reports
- Log critical decisions, notifications and changing conditions during response
Participants can apply an incident command structure to workplace fire scenarios.
- Incident Command System roles: command, operations, planning, logistics and finance
- Establish command post location, authority transfer and situation briefing procedures
- Set incident objectives using life safety, incident stabilisation and property protection
- Create an incident action plan with assignments and communication channels
- Coordinate handover information for responding fire and rescue services
- Maintain responder safety through accountability, exclusion zones and hazard updates
Participants can coordinate response-team actions without exceeding safe role boundaries.
- Define response-team capabilities, limitations, equipment and standby arrangements
- Assign access control, traffic management, first aid and accountability functions
- Integrate security, facilities, medical and operational personnel during alarms
- Establish emergency vehicle access routes and responder entry information
- Manage utilities isolation decisions for electricity, gas, fuel and ventilation
- Apply stop-work authority when conditions threaten responders or occupants
Participants can develop controls for fire scenarios involving specialised workplace hazards.
- Assess flammable-liquid transfer, dispensing, bonding and grounding controls
- Control lithium-ion battery charging, storage, damage and thermal runaway risks
- Plan fire precautions for confined spaces, laboratories and process areas
- Review dust explosion hazards using housekeeping, containment and ignition control
- Specify contractor fire controls for hot work and temporary installations
- Address cooking, generator, fuel storage and waste-compactor fire scenarios
Participants can conduct a documented fire safety inspection and prioritise corrective actions.
- Build inspection checklists covering prevention, protection, escape and management controls
- Verify inspection frequencies against equipment registers and maintenance records
- Identify deficiencies in fire doors, penetrations, signage and emergency lighting
- Classify findings by immediate danger, major deficiency and planned improvement
- Write corrective actions with accountable owners, due dates and evidence requirements
- Escalate overdue life-safety actions through management review and risk acceptance
Participants can plan and evaluate drills using measurable evacuation performance criteria.
- Set drill objectives for notification, evacuation, accountability and communications
- Prepare drill scenarios without compromising safety or causing unnecessary alarm
- Measure alarm recognition, exit flow, assembly completion and accountability times
- Observe warden actions, blocked exits, communication failures and unsafe behaviours
- Conduct hot debriefs using facts, observations, actions and assigned owners
- Trend drill findings to target refresher training and system improvements
Participants can investigate fire-related events and manage immediate recovery actions.
- Secure incident scenes while preserving evidence and protecting affected personnel
- Collect witness accounts using chronology, open questions and corroboration
- Apply five whys and barrier analysis to identify causal factors
- Distinguish immediate causes, underlying causes and failed control measures
- Develop corrective actions using hierarchy of controls and verification dates
- Plan re-entry decisions, damage assessment and business continuity communications
Participants can integrate fire safety controls into an occupational health and safety management system.
- ISO 45001 planning links between hazards, risks, objectives and controls
- Assign fire safety responsibilities within organisational roles and reporting lines
- Control documents through approval, distribution, revision and retention procedures
- Use leading indicators for inspections, impairments, training and drill performance
- Review contractor controls within procurement, permit and induction processes
- Prepare management review inputs from incidents, audits and action trends
Participants can assemble and quality-check a site emergency plan before formal approval.
- Structure emergency plans around activation, command, evacuation and recovery
- Include site maps, contacts, assembly areas and emergency equipment locations
- Align response procedures with local emergency-service information requirements
- Test plan consistency between alarm procedures, warden duties and communications
- Review plan assumptions against occupancy changes, construction and operational change
- Obtain approval, distribute controlled copies and schedule periodic review
Participants can build, review and present a complete site fire safety and emergency response plan.
- Consolidate risk assessment findings into prioritised prevention and protection controls
- Prepare evacuation maps, warden assignments and accountability arrangements
- Define alarm response, incident command and emergency-service liaison procedures
- Specify inspection, maintenance, impairment and drill assurance schedules
- Present plan decisions against realistic fire scenarios and stakeholder questions
- Revise the final plan using peer review and instructor feedback
Exercises and examples are adapted to each cohort's sectors and roles.