Course modules
10 modules over 5 daysParticipants can identify the conditions that start, sustain and spread workplace fires.
- Combustion chemistry: fuel, oxygen, heat and chain-reaction interruption methods
- Classifying Class A, B, C, D and F fire hazards
- Heat transfer by conduction, convection, radiation and direct flame contact
- Flash point, fire point, autoignition temperature and vapour-density implications
- Reading fire incident data to identify recurring ignition sources
- Fire growth stages, smoke movement and tenability limits
Participants can define fire safety responsibilities, evidence requirements and applicable control obligations.
- Employer, duty-holder and competent-person responsibilities under applicable fire law
- ISO 45001 operational planning links to fire risk controls
- Identifying applicable building, electrical and fire-code requirements
- Documenting reasonable precautions, inspection evidence and corrective-action ownership
- Contractor control arrangements for hot work and temporary fire hazards
- Consultation duties, safety committees and workforce reporting channels
Participants can complete a structured fire risk assessment and assign proportionate controls.
- Five-step fire risk assessment: identify, evaluate, control, record, review
- Zoning premises by occupancy, fuel load, ignition and vulnerability
- Evaluating likelihood and consequence with a risk matrix
- Identifying people at risk, including visitors and mobility-impaired occupants
- Control hierarchy applied to ignition, fuel and oxygen sources
- Recording residual risk, control owners, deadlines and review triggers
Participants can inspect passive fire precautions and identify defects affecting safe escape.
- Compartmentation principles: fire-resisting walls, floors, doors and service penetrations
- Inspecting fire doors, smoke seals, closers and hold-open devices
- Fire stopping methods for cables, ducts, pipes and structural joints
- Means-of-escape design: travel distance, width, exits and protected routes
- Smoke control, dampers and stair pressurisation system purposes
- Recognising defects requiring specialist inspection or immediate interim controls
Participants can assess the purpose, operation and assurance needs of alarm arrangements.
- Detection objectives: life safety, property protection and business continuity
- Manual call points, automatic detectors and alarm zoning logic
- Detector selection for smoke, heat, flame and multisensor applications
- NFPA 72 concepts for testing, inspection and alarm documentation
- Emergency voice communication, alarm audibility and visual notification requirements
- Managing false alarms without disabling necessary protection
Participants can select suitable suppression controls and define safe first-aid firefighting limits.
- Suppression principles: cooling, smothering, oxygen reduction and chemical inhibition
- Portable extinguisher selection using fire class and agent compatibility
- NFPA 10 inspection tags, monthly checks and maintenance records
- Sprinkler system components, water supplies and control-valve supervision
- Special hazards protection for kitchens, flammable liquids and electrical rooms
- Safe first-aid firefighting limits and evacuation decision criteria
Participants can prepare and test emergency arrangements suited to their occupancy and risks.
- Emergency response plan roles: incident commander, wardens, marshals and first aiders
- Evacuation strategies: simultaneous, phased, horizontal and defend-in-place options
- Personal Emergency Evacuation Plans for mobility and sensory needs
- Assembly-point control, roll calls and missing-person escalation procedures
- Emergency services liaison, site information packs and appliance access
- Tabletop testing, drill observation and post-drill corrective actions
Participants can establish inspection routines and manage impaired fire protection safely.
- NFPA 25 concepts for water-based system inspection and testing
- Planned preventive maintenance schedules for alarms, doors and extinguishers
- Impairment permits, fire watch and compensatory control requirements
- Inspection checklists for escape routes, storage and ignition control
- Defect prioritisation using life-safety impact, urgency and repair ownership
- Contractor service reports verified against asset registers and acceptance criteria
Participants can investigate fire events and convert findings into verified preventive actions.
- Initial incident scene preservation, reporting and evidence collection
- Timeline reconstruction using witness accounts, logs, photographs and alarms
- Five Whys and barrier analysis for causal-factor identification
- Corrective and preventive action plans with measurable closure evidence
- Business continuity priorities following fire, smoke or water damage
- Lessons-learned communication that prevents recurrence without assigning blame
Participants can organise fire safety assurance activities and prepare a workplace improvement plan.
- Fire safety management system elements, policy commitments and performance indicators
- Leading indicators: overdue inspections, impairment hours and drill findings
- Annual review calendar for assessments, training, testing and governance
- Budgeting control improvements by risk reduction, legal duty and asset criticality
- Management review packs using trends, exceptions and action status
- Individual 90-day application plan with milestones and accountable owners
Exercises and examples are adapted to each cohort's sectors and roles.