Course modules
20 modules over 10 daysParticipants can explain how fires start, develop and affect people, buildings and evacuation decisions.
- Fire triangle, tetrahedron and heat transfer mechanisms affecting ignition control
- Classify Class A, B, C, D and F fire hazards
- Combustible loading calculations using floor area, materials and storage heights
- Identify ignition sources through task observation and energy isolation review
- Fire development stages from incipient ignition through flashover and decay
- Smoke movement, toxic products and tenability criteria during enclosure fires
Participants can assign fire safety responsibilities and identify applicable legal and standards-based requirements.
- Employer, occupier, manager and employee duties within fire safety governance
- Apply ISO 45001 risk management principles to fire safety arrangements
- NFPA 101 life safety concepts for occupancy and means of egress
- NFPA 72 requirements for fire alarm notification and supervisory signals
- Local authority approvals, inspections and enforcement documentation requirements
- Duty-holder matrices linking fire controls, inspections and corrective actions
Participants can complete a documented fire risk assessment using a structured assessment process.
- Five-step fire risk assessment process from hazards through review
- Define credible fire scenarios using people, fuel, ignition and location
- Assess likelihood and consequence using a calibrated risk matrix
- Record existing controls, deficiencies, actions, owners and completion dates
- Prioritise corrective actions using risk ranking and implementation feasibility
- Set review triggers after process changes, incidents and occupancy changes
Participants can specify preventive controls for common workplace ignition and fuel hazards.
- Electrical safety controls for overloaded circuits, damaged cables and temporary supplies
- Hot work permit controls covering preparation, fire watch and closeout
- Flammable liquid storage using segregation, quantities and ignition source control
- Waste management routines preventing combustible accumulation and blocked escape routes
- Smoking controls, designated areas and disposal arrangements for ignition prevention
- Oxygen enrichment hazards from cylinders, oxidisers and medical gas systems
Participants can inspect passive fire protection features and identify common failures.
- Compartmentation principles limiting smoke and fire spread between building zones
- Fire-resisting walls, floors and ceilings assessed for integrity breaches
- Fire doors checked for self-closing, gaps, damage and obstruction
- Penetration sealing requirements around cables, pipes and building services
- Protected shafts, risers and stairwells maintained as fire-resisting enclosures
- Interpret fire safety drawings, compartment plans and door schedules
Participants can evaluate whether detection, alarm and lighting arrangements support timely evacuation.
- Manual call points, automatic detectors and alarm zones explained
- Detector selection for smoke, heat, flame and aspirating systems
- Alarm audibility, visual signals and accessibility for hearing-impaired occupants
- Emergency lighting coverage for escape routes, stairways and external assembly areas
- Cause-and-effect matrices linking detection zones to emergency system responses
- Fault reporting, impairment controls and temporary compensatory measures
Participants can select extinguishers and define safe limits for first-aid firefighting.
- Extinguisher media selection for ordinary combustibles, liquids, gases and metals
- Rating systems, travel distances and extinguisher placement principles
- PASS technique applied within safe escape and visibility limits
- Recognise conditions requiring immediate evacuation rather than firefighting intervention
- Inspection checks for pressure, pins, hoses, labels and service dates
- Fire blanket, hose reel and fixed suppression system limitations
Participants can assess escape routes and develop practical evacuation arrangements.
- Calculate occupant loads using floor area, function and peak occupancy
- Assess travel distance, exit capacity and alternative escape route availability
- Escape route inspections covering obstructions, signage, lighting and door operation
- Assembly point selection using access, wind direction and emergency vehicle routes
- Roll-call methods for employees, visitors, contractors and remote workgroups
- Phased, simultaneous and zoned evacuation strategies for complex premises
Participants can prepare emergency response plans with clear roles, actions and escalation points.
- Emergency response plan structure covering alarm, evacuation and incident escalation
- Incident command roles for incident controller, wardens and communications coordinators
- Initial action checklists for fire, smoke, explosion and alarm malfunction
- Decision thresholds for evacuation, sheltering, partial closure and emergency shutdown
- Emergency contact directories including fire service, utilities and specialist contractors
- Control room logs recording events, decisions, communications and handovers
Participants can develop concise emergency messages for occupants, responders and management.
- Alarm messages distinguishing evacuation, alert, standby and all-clear instructions
- Plain-language emergency announcements for occupants under stress and time pressure
- Communication trees linking wardens, managers, security and emergency services
- Media holding statements protecting facts, privacy and operational integrity
- Family liaison principles following injury, fatality or prolonged site closure
- Post-incident staff communications addressing return-to-work and support arrangements
Participants can plan inclusive evacuation arrangements for people requiring assistance.
- Personal Emergency Evacuation Plans for employees needing individual assistance
- Generic Emergency Evacuation Plans for visitors and unidentified occupants
- Refuge areas, evacuation chairs and communication equipment selection criteria
- Assign buddies and assistants without creating unsafe dependency arrangements
- Mobility, sensory, cognitive and temporary impairment considerations during evacuation
- Confidentiality controls for personal evacuation information and assistance records
Participants can define, train and support emergency role holders for effective response.
- Warden area assignments based on floors, zones and occupant distribution
- Sweep procedures checking rooms, toilets, meeting spaces and isolated areas
- Warden equipment lists including identifiers, torches, radios and checklists
- Shift coverage planning for weekends, night work and absenteeism
- Briefing protocols for visitors, contractors and temporary workforce personnel
- Role competency matrices covering induction, refresher training and assessment
Participants can plan, observe and evaluate drills that test emergency arrangements realistically.
- Drill objectives linked to evacuation speed, accountability and communication performance
- Exercise design using announced, unannounced and table-top drill formats
- Observer checklists recording alarm response, route use and warden actions
- Measure evacuation performance without encouraging unsafe rushing or congestion
- Hot debrief methods capturing observations immediately after exercise completion
- Corrective action registers assigning owners, deadlines and verification evidence
Participants can prepare site information and access arrangements for emergency responders.
- Premises information boxes containing plans, hazards, contacts and utility details
- Fire appliance access routes, turning areas and hydrant availability checks
- Site plans marking hazardous materials, shutoffs, muster points and control rooms
- Utility isolation procedures for electricity, gas, fuel and process systems
- Responder briefings covering occupancy status, missing persons and incident hazards
- Joint familiarisation visits with fire services and security personnel
Participants can establish inspection and maintenance controls for key fire safety measures.
- Planned preventive maintenance schedules for alarms, extinguishers and emergency lighting
- Inspection frequencies based on manufacturer instructions, codes and risk exposure
- Impairment management permits for disabled alarms, sprinklers and fire doors
- Defect classification separating critical, major and routine corrective actions
- Contractor service reports reviewed against scope, findings and completion evidence
- Compliance dashboards tracking overdue inspections, defects and closure performance
Participants can control elevated fire risks created by contractors and temporary work.
- Hot work permit authorisation, gas testing and combustible removal requirements
- Fire watch duration determined by work type, location and residual heat
- Contractor induction covering alarms, escape routes and emergency reporting
- Temporary structures, generators and electrical leads assessed for fire hazards
- Construction fire safety plans addressing changing routes and incomplete protection
- Handover controls after maintenance, shutdowns and fire system modifications
Participants can assess additional controls for specialised fire hazards and occupancies.
- Lithium-ion battery charging risks, thermal runaway and segregation controls
- Commercial kitchen hazards involving grease, extraction and suppression systems
- Data centre fire protection for electrical rooms and critical equipment
- Laboratory controls for flammables, compressed gases and incompatible chemicals
- Warehouse storage configurations affecting sprinkler performance and fire spread
- Healthcare evacuation priorities for patients requiring clinical support equipment
Participants can investigate fire events and translate findings into recovery and prevention actions.
- Secure incident scenes while preserving evidence and maintaining access control
- Timeline analysis reconstructing detection, decisions, evacuation and response actions
- Five Whys and barrier analysis applied to fire control failures
- Witness interview methods separating observations, assumptions and recollections
- Recovery priorities for life safety, building access, operations and communications
- Lessons-learned reports linking root causes to verified corrective actions
Participants can monitor fire safety performance and report assurance information to management.
- Leading indicators covering inspections, training, drills and action closure
- Lagging indicators for fires, false alarms, injuries and property damage
- Audit protocols testing documents, physical controls and staff knowledge
- Management review reports presenting risks, trends, resources and decisions
- Assurance sampling methods for large estates and multi-site operations
- Annual fire safety review cycle aligned with organisational risk governance
Participants can build, review and present a complete fire safety and emergency preparedness package for a defined workplace.
- Define premises profile, occupancy, hazards and credible fire scenarios
- Complete a documented fire risk assessment with prioritised control actions
- Develop evacuation strategy, warden assignments and accountability arrangements
- Prepare emergency response procedures, contact lists and communication scripts
- Create inspection schedules, drill plans and corrective action registers
- Present the package for peer review, challenge and management approval
Exercises and examples are adapted to each cohort's sectors and roles.