Course modules
20 modules over 10 daysParticipants can explain how policy, technology, demand and market design shape renewable energy decisions.
- Decarbonisation pathways linked to electricity demand, electrification and energy security
- Power-system value chain from generation assets through retail electricity supply
- Merit-order pricing and wholesale market effects of variable generation
- Capacity markets, ancillary services and flexibility revenue fundamentals
- Carbon pricing mechanisms affecting fossil generation and renewable investment cases
- PESTLE assessment of transition drivers, constraints and strategic uncertainties
Participants can compare major renewable technologies against operational and strategic requirements.
- Solar photovoltaic configurations: rooftop, ground-mounted, floating and agrivoltaic systems
- Onshore and offshore wind turbine characteristics, siting and yield factors
- Hydropower, geothermal and sustainable bioenergy technology selection criteria
- Green hydrogen production pathways, electrolyser economics and end-use demand
- Marine energy and advanced geothermal maturity assessed using technology readiness levels
- Technology screening matrix balancing cost, maturity, emissions and local constraints
Participants can interpret resource data and estimate generation uncertainty for renewable projects.
- Solar irradiance measures: GHI, DNI, plane-of-array and seasonal variability
- Wind resource assessment using hub-height speeds, direction and turbulence intensity
- Capacity factor calculated from expected generation and rated asset capacity
- P50 and P90 yield estimates applied to lender risk assessment
- Loss assumptions covering shading, soiling, wake effects and availability
- Satellite datasets, meteorological stations and bankable measurement campaign requirements
Participants can assess solar PV design, performance and delivery considerations.
- Site constraints assessed through orientation, shading, land-use and geotechnical reviews
- Module technologies compared: monocrystalline, bifacial, thin-film and degradation rates
- Inverter selection, DC-AC ratio and clipping loss calculations
- Performance ratio used to diagnose solar plant generation efficiency
- Preliminary layout considers access roads, drainage, setbacks and cable routes
- Construction risk register covering procurement, weather, permits and commissioning
Participants can assess wind project viability from site screening through operating performance.
- Wind farm micrositing balances energy capture, wakes, setbacks and access
- Turbine power curves translated into annual energy production estimates
- Wake-loss modelling assumptions tested against layout and prevailing wind direction
- Environmental surveys address birds, bats, noise and visual impact
- Balance-of-plant scope includes foundations, roads, substations and collection systems
- Operations plans cover predictive maintenance, spare parts and availability guarantees
Participants can determine where storage and demand flexibility improve renewable energy value.
- Lithium-ion battery architecture: cells, modules, inverters and battery management systems
- Storage duration matched to peak shifting, arbitrage and resilience requirements
- Round-trip efficiency, degradation and cycle life included in economics
- Dispatch strategy compares self-consumption, demand charges and market revenues
- Demand response baselines established from interval-metered consumption data
- Pumped hydro, thermal storage and long-duration alternatives compared systematically
Participants can identify grid constraints and integration measures for variable renewable projects.
- Interconnection studies examine hosting capacity, fault levels and voltage control
- Curtailment risk quantified using grid congestion and dispatch assumptions
- Frequency response, inertia and reserve requirements for inverter-based generation
- Grid codes specify ride-through, reactive power and protection settings
- Transmission planning links renewable resource zones with demand centres
- Flexibility stack combines storage, interconnection, demand response and forecasting
Participants can calculate and interpret project costs, revenues and economic performance measures.
- Levelized cost of energy calculated from lifecycle costs and generation
- CAPEX breakdown covers equipment, civil works, interconnection and development costs
- OPEX assumptions include maintenance, insurance, land leases and asset management
- Net present value and internal rate of return compared
- Sensitivity analysis tests power price, yield, inflation and capital cost
- Merchant revenue forecasts separated into energy, capacity and ancillary-service streams
Participants can structure an investment case and assess financing risks for renewable projects.
- Project finance cash flows distinguish construction, operations and debt service
- Debt service coverage ratio tested against downside generation scenarios
- Equity returns assessed through distributions, residual value and exit assumptions
- Weighted average cost of capital reflects country, technology and contract risk
- Term sheets reviewed for covenants, security, repayment and reserve accounts
- Investment committee papers present assumptions, sensitivities and approval conditions
Participants can assess regulatory exposure and plan permissions for renewable energy projects.
- Renewable support mechanisms compared: auctions, feed-in tariffs and tax credits
- Auction design influences bid pricing, completion risk and market concentration
- Permitting sequence maps land rights, environmental approvals and grid consent
- Environmental and social impact assessment identifies material project effects
- Local-content rules and import duties tested within procurement strategies
- Regulatory risk register assigns owners, triggers and response actions
Participants can select procurement routes that match demand, risk appetite and emissions objectives.
- Load profile analysis identifies baseload, peaks and operational flexibility
- Onsite generation screened against roof area, land access and demand coincidence
- Physical PPAs compared with sleeved, virtual and direct-wire structures
- Contract-for-difference mechanics separate fixed-price certainty from market settlement
- Renewable energy certificates evaluated for quality, vintage and retirement evidence
- Procurement decision tree matches contract structures to organisational priorities
Participants can review PPA commercial terms and identify material risk allocation issues.
- PPA pricing models include fixed, indexed, floor-and-collar and pay-as-produced
- Volume risk allocated through shaped, baseload and as-generated delivery terms
- Settlement provisions address imbalance charges, curtailment and negative pricing
- Credit support covers parent guarantees, letters of credit and collateral
- Change-in-law clauses allocate policy, tax and regulatory exposure
- Contract review checklist identifies termination, force majeure and step-in rights
Participants can connect renewable procurement decisions with credible greenhouse-gas reporting.
- GHG Protocol Scope 2 location-based and market-based methods compared
- Quality criteria assess contractual instruments, exclusivity and certificate retirement
- Residual mix factors prevent double counting in electricity emissions claims
- Avoided-emissions estimates separated from reported inventory emissions reductions
- Carbon accounting controls document meter data, contracts and assurance evidence
- Claims review distinguishes renewable electricity use from carbon neutrality statements
Participants can address supply-chain, environmental and community risks in project planning.
- Critical minerals exposure assessed for lithium, nickel, copper and rare earths
- Supplier due diligence reviews labour, traceability and environmental performance evidence
- Lifecycle assessment compares embodied emissions, operations and end-of-life treatment
- Circularity plans cover module reuse, turbine blades and battery recycling
- Stakeholder mapping identifies affected communities, authorities and rights holders
- Benefit-sharing mechanisms include local jobs, community funds and ownership models
Participants can assess physical climate risks and build resilience measures into renewable assets.
- Physical risk assessment considers heat, flooding, drought, storms and wildfire
- Climate scenarios test asset performance under changing weather distributions
- Site design adapts drainage, cooling, foundations and fire protection measures
- Insurance requirements reflect catastrophe exposure, deductibles and business interruption
- TCFD-aligned disclosures connect climate risks with financial planning assumptions
- Business continuity plans define outage response, communications and recovery priorities
Participants can formulate a phased renewable energy strategy using strategic and financial evidence.
- Energy baseline combines consumption, costs, emissions and contractual commitments
- Abatement cost curve ranks measures by cost, carbon and implementation timing
- Strategic scenarios compare self-generation, PPAs, certificates and efficiency investments
- Portfolio diversification balances technologies, geographies, counterparties and contract tenors
- Decision criteria weight economics, resilience, emissions, feasibility and stakeholder acceptance
- Strategy roadmap sequences quick wins, development projects and long-term commitments
Participants can establish governance, controls and delivery plans for renewable energy programmes.
- RACI matrix assigns decision rights, approvals and delivery accountabilities
- Stage-gate governance controls progression from screening through investment approval
- Work breakdown structure defines development, procurement, construction and operations tasks
- Risk register scores probability, impact, mitigations and accountable owners
- Key performance indicators track generation, savings, emissions and delivery milestones
- Benefits-realisation plan links project outputs with financial and carbon outcomes
Participants can use operational data to monitor renewable performance and improve decisions.
- SCADA data architecture connects sensors, meters, gateways and supervisory systems
- Generation forecast accuracy measured using mean absolute percentage error
- Performance benchmarking compares actual yield against budget and weather-normalised expectations
- Availability losses classified by grid, equipment, weather and planned maintenance
- Dashboard design links executive metrics with operational exception reporting
- Data-quality checks identify missing intervals, meter errors and timestamp inconsistencies
Participants can prepare decision materials that address financial, technical and stakeholder concerns.
- Board paper structure states decision, rationale, options and recommendation
- Investment narrative connects energy costs, resilience, emissions and strategic priorities
- Waterfall charts explain savings drivers, cost changes and uncertainty ranges
- Risk heat maps communicate material exposures and planned mitigations
- Stakeholder messages adapted for finance, operations, communities and regulators
- Approval presentation rehearses challenge questions on assumptions and trade-offs
Participants can build, review and present a complete renewable energy strategy pack for a defined organisation or asset portfolio.
- Define organisational demand baseline, strategic objectives and decision constraints
- Select technology and procurement options using weighted evaluation criteria
- Build lifecycle cost model with yield, price and financing assumptions
- Prepare implementation roadmap, governance structure and risk response plan
- Review emissions claims against GHG Protocol Scope 2 requirements
- Present investment recommendation, sensitivities and decision requests to stakeholders
Exercises and examples are adapted to each cohort's sectors and roles.








