Course modules
10 modules over 5 daysParticipants can structure an energy review that identifies significant energy uses and data gaps.
- Energy-use mapping from utility bills, interval data and process flow diagrams
- SEUs and relevant variables identified using ISO 50001 terminology
- Energy review boundaries, sources, meters and data-quality limitations
- Material energy balance links fuel, electricity, steam and production
- Pareto analysis ranks significant energy uses by annual cost
- Baseline period selection accounts for operating changes and missing data
Participants can define the governance, documentation and management processes required for an energy management system.
- ISO 50001 clauses translated into an energy management system
- Context, interested parties and scope documented for certification-ready governance
- Energy policy commitments aligned with procurement, maintenance and capital planning
- Roles, competence and communication matrices assign accountable energy-management responsibilities
- Document control and retained information support auditable management-system evidence
- Management review inputs connect objectives, performance trends and corrective actions
Participants can develop energy performance indicators and baselines that account for material operational variation.
- ISO 50006 EnPIs selected for facilities, processes and utility systems
- Simple ratio indicators tested against production and weather distortion
- Regression models establish weather-normalised energy performance indicators
- Relevant variables screened using scatterplots, residuals and engineering judgement
- Static and adjusted baselines distinguish improvement from operational variation
- Normalization rules record changes in equipment, occupancy and product mix
Participants can specify metering arrangements and data controls that support energy performance decisions.
- Meter hierarchies connect main supplies, submeters and significant energy uses
- Measurement plans specify points, intervals, accuracy and data ownership
- Electricity load profiles reveal baseload, peaks and avoidable demand
- Thermal surveys combine temperature, pressure, flow and combustion readings
- Data validation checks missing intervals, clock errors and implausible values
- Dashboard specifications distinguish operational alarms from monthly management reporting
Participants can conduct structured energy audits and document improvement opportunities consistently.
- Walk-through audits follow ISO 50002 evidence and reporting requirements
- Opportunity registers capture condition, cause, measure, savings and constraints
- Compressed-air leak surveys quantify losses using ultrasound and run-hours
- Steam-trap inspections classify failures, blow-through and maintenance priorities
- HVAC control reviews test schedules, setpoints, deadbands and economiser operation
- Motor-system assessments examine loading, controls, rewinding and replacement decisions
Participants can evaluate energy projects and establish credible savings measurement arrangements.
- Life-cycle cost analysis compares efficient equipment with lowest-price alternatives
- Net present value, IRR and payback tested against investment hurdles
- Marginal abatement cost curves rank measures by cost and emissions
- IPMVP options A through D match measurement approaches to projects
- Measurement and verification plans define boundaries, adjustments and uncertainty
- Savings registers separate avoided consumption, cost savings and emissions reductions
Participants can analyse utility charges and identify demand-side energy cost reduction options.
- Tariff analysis separates energy charges, demand charges, taxes and penalties
- Load-shifting options target peak-demand windows and time-of-use periods
- Power-factor correction assessed against utility tariffs and harmonic risks
- Demand-response readiness evaluates controllable loads, notices and operational limits
- Energy procurement data reconciled with invoices, contracts and meter records
- On-site solar generation assessed against load shape and export rules
Participants can screen common technical measures for buildings, utilities and process systems.
- Boiler efficiency calculations use excess oxygen, stack temperature and blowdown
- Heat-recovery screening identifies exchanger duties, pinch points and fouling
- Variable-speed drive suitability assessed from pump and fan affinity laws
- Refrigeration reviews address suction pressure, defrost, floating head and leakage
- Building fabric measures prioritise air leakage, insulation and solar gains
- Controls sequences reduce simultaneous heating, cooling and unnecessary run-time
Participants can convert approved opportunities into controlled operational improvement actions.
- Energy objectives translated into SMART targets, action owners and deadlines
- Capital requests present baselines, savings, risks, costs and approvals
- Operational controls embed energy criteria within standard operating procedures
- Maintenance plans include lubrication, calibration, cleaning and control verification
- Training matrices target operators, technicians, supervisors and energy champions
- Behaviour-change campaigns use feedback, prompts, commitments and recognition
Participants can review energy performance, address nonconformities and maintain an improvement roadmap.
- Internal audit programmes test ISO 50001 conformity and implementation evidence
- Nonconformities distinguish correction, root cause, corrective action and effectiveness
- Five Whys and fishbone diagrams investigate recurring energy-performance failures
- Monthly review packs combine EnPIs, project status, savings and risks
- Application plans sequence quick wins, studies, investments and governance actions
- Quarterly improvement cycles revise baselines, targets and measurement plans
Exercises and examples are adapted to each cohort's sectors and roles.