Course modules
20 modules over 10 daysParticipants can define workplace environmental hazards, exposure pathways and control responsibilities.
- Environmental hazards, occupational exposures and pollution pathways distinguished clearly
- Sources, receptors and transport pathways mapped using source-pathway-receptor models
- Direct, indirect, normal and abnormal environmental aspects classified
- Worker health, community and ecological consequences compared systematically
- Duty holders and control accountabilities assigned through responsibility matrices
- Site boundaries, sensitive receptors and operational interfaces identified early
Participants can build a practical legal and permit compliance register for environmental hazards.
- Legal registers structured around applicable acts, regulations, permits and conditions
- Permit limits translated into operating controls and monitoring requirements
- Environmental duty-of-care obligations applied to waste storage and transfer
- Regulator inspection powers, notices and evidence requirements examined
- Compliance obligations linked to processes, locations and responsible roles
- Retention periods established for monitoring records, manifests and incident evidence
Participants can identify environmental hazards using structured workplace review methods.
- Process mapping traces inputs, activities, outputs, wastes and emissions
- Task observations identify release points during routine and non-routine work
- Workplace inspections use area-based environmental hazard checklists systematically
- Job hazard analysis captures worker exposure and environmental release scenarios
- Safety data sheets reveal chemical hazards, incompatibilities and disposal constraints
- Previous incidents, complaints and near misses inform hazard identification
Participants can create a usable register connecting activities, hazards, receptors and controls.
- Register fields capture activity, aspect, hazard, receptor and consequence
- Significant aspects ranked using defined significance screening criteria
- Existing controls recorded with ownership, status and verification evidence
- Abnormal operations included: start-up, shutdown, maintenance and emergencies
- Contractor activities entered where site environmental controls may be affected
- Register reviews triggered by changes, incidents and monitoring results
Participants can assess environmental hazard risks and prioritise corrective actions.
- Likelihood-consequence matrices calibrated for people, environment, assets and reputation
- Inherent and residual risk scores distinguished before and after controls
- Exposure frequency, duration and concentration considered within risk estimates
- Risk tolerability criteria set escalation thresholds for management decisions
- Bow-Tie analysis identifies threats, barriers, consequences and recovery controls
- Action priorities assigned using risk ratings, legal duties and feasibility
Participants can select proportionate environmental hazard controls and verify their performance.
- Hierarchy of controls applied before reliance on procedures or PPE
- Elimination and substitution assessed during process and product selection
- Engineering controls specified through containment, extraction, isolation and automation
- Administrative controls define operating limits, inspections and permit requirements
- Control criticality identified for barriers preventing major releases
- Verification methods confirm controls remain available, suitable and effective
Participants can control chemical hazards from receipt through storage, use and disposal.
- Chemical inventories reconcile containers, quantities, locations and hazard classifications
- Globally Harmonized System labels and pictograms interpreted for control decisions
- Compatibility matrices separate acids, bases, oxidisers, fuels and reactives
- Secondary containment sized for credible leaks and storage arrangements
- Chemical transfer procedures control spills, vapours, static and overfilling
- Waste characterisation determines segregation, labelling, storage and disposal routes
Participants can identify airborne hazards and specify basic ventilation control measures.
- Airborne dust, vapour, mist, fume and gas hazards distinguished
- Exposure routes assessed through inhalation, skin contact and ingestion
- Local exhaust ventilation components examined from hood to discharge point
- Capture velocity, enclosure and make-up air affect control performance
- General ventilation limitations recognised for high-toxicity airborne contaminants
- Air monitoring strategies define personal, area and source sampling
Participants can assess physical environmental agents and propose exposure controls.
- Noise sources characterised by sound level, frequency and exposure duration
- Dosimetry and area surveys support noise exposure assessment decisions
- Hand-arm and whole-body vibration hazards linked to equipment use
- Thermal stress evaluated using workload, humidity, radiant heat and clothing
- Ionising and non-ionising radiation sources controlled through time-distance-shielding
- Physical-agent controls prioritise equipment design, isolation and maintenance
Participants can identify biological and indoor environmental hazards requiring control.
- Biological agents classified by source, transmission route and health effect
- Legionella control plans address water systems, temperatures and sampling
- Mould growth investigations consider moisture sources, materials and occupant exposure
- Indoor air quality indicators include carbon dioxide, particulates and volatile compounds
- Cleaning, waste handling and laundry activities assessed for biological exposure
- Immunisation, hygiene and containment controls matched to exposure risks
Participants can design controls for waste generation, segregation, storage and transfer.
- Waste streams mapped from generation point to final treatment route
- Waste hierarchy applied through prevention, reduction, reuse, recycling and disposal
- Segregation systems prevent incompatible mixing and contaminated recycling streams
- Container labelling identifies contents, hazards, dates and responsible owners
- Storage inspections check containment, access, weather protection and housekeeping
- Transfer documentation maintains traceability from site collection to disposal
Participants can control hazards affecting drains, watercourses, soil and air emissions.
- Drainage plans distinguish foul, surface-water, process and intercepting systems
- Potential pollutants traced from operational areas to receiving environments
- Oil-water separators inspected for capacity, maintenance and bypass risks
- Stack emissions controlled through process parameters, filtration and maintenance
- Soil contamination risks assessed around storage, loading and waste areas
- Discharge monitoring plans define parameters, locations, frequency and action limits
Participants can manage environmental hazards associated with hazardous materials and legacy conditions.
- Asbestos-containing materials identified through surveys, registers and condition assessments
- Lead, silica and mercury hazards assessed during disturbance activities
- Contaminated land indicators include staining, odours, fill and historical uses
- Suspect materials managed through exclusion, sampling and specialist advice
- Demolition and refurbishment controls prevent uncontrolled hazardous material releases
- Chain-of-custody procedures protect integrity of environmental samples and records
Participants can prepare a monitoring programme that produces actionable control evidence.
- Monitoring objectives distinguish compliance, exposure assessment and control verification
- Sampling plans define parameters, locations, timing, methods and responsibilities
- Direct-reading instruments compared with laboratory analysis and passive sampling
- Calibration, zero checks and maintenance support reliable field measurements
- Detection limits and uncertainty considered when interpreting monitoring results
- Trend charts identify deterioration, recurring excursions and emerging priorities
Participants can prepare response arrangements for credible environmental release events.
- Spill scenarios developed from chemicals, quantities, drains and receptors
- Spill prevention controls include bunds, shut-off valves and transfer checks
- Emergency response plans assign notification, containment and recovery responsibilities
- Drain covers, absorbents and overpacks selected for likely release materials
- Escalation criteria define regulator notification and community communication requirements
- Post-incident sampling confirms cleanup effectiveness and residual contamination status
Participants can investigate environmental incidents and establish effective corrective actions.
- Initial incident evidence preserved through photographs, samples and witness accounts
- Timeline analysis reconstructs conditions, decisions, barriers and release progression
- Five Whys and causal factor analysis distinguish symptoms from causes
- Barrier failures examined using Bow-Tie preventive and recovery controls
- Corrective actions specify owners, deadlines, verification and effectiveness criteria
- Lessons learned communicated through targeted briefings, procedures and inspections
Participants can connect hazard controls to ISO management system requirements.
- ISO 14001 clauses linked to aspects, compliance obligations and operational control
- ISO 45001 interfaces address worker exposure and environmental hazard management
- Documented information controlled through approval, revision and point-of-use access
- Objectives and targets derived from significant aspects and risk priorities
- Management of change reviews new materials, equipment and process conditions
- Operational controls translated into procedures, permits and inspection standards
Participants can manage environmental hazards introduced by contractors, suppliers and changes.
- Prequalification reviews contractor competence, environmental records and control arrangements
- Scope-of-work documents define waste, emissions and spill prevention requirements
- Permit-to-work interfaces address hazardous substances, drains and containment controls
- Procurement specifications consider safer substitutes, packaging and end-of-life disposal
- Change reviews assess new hazards, receptors, controls and monitoring needs
- Contractor inspections verify housekeeping, storage and emergency preparedness requirements
Participants can assure environmental hazard controls through inspection, audit and review.
- Inspection schedules prioritise significant hazards, critical controls and legal conditions
- Audit criteria compare documented arrangements with observed operating conditions
- Sampling records tested for completeness, traceability and action-limit compliance
- Nonconformities graded by risk, legal exposure and control failure
- Key performance indicators track releases, waste, inspections and corrective actions
- Management reviews evaluate trends, resources, risks and improvement priorities
Participants can build, review and present a complete workplace environmental hazard control pack for a defined site or activity.
- Site profile defines activities, boundaries, receptors and regulatory obligations
- Hazard register documents significant aspects, exposure pathways and existing controls
- Risk assessments prioritise credible scenarios using agreed rating criteria
- Control plan specifies hierarchy-based actions, owners, resources and deadlines
- Monitoring schedule sets parameters, methods, frequencies, limits and escalation
- Emergency arrangements address spill scenarios, notifications and recovery actions
Exercises and examples are adapted to each cohort's sectors and roles.